Synthes pelvic inventory

The DePuy Synthes 3.5 mm Intrapelvic Acetabular Plates are indicated for fractures of the acetabulum in adults and adolescents (greater than 12 through 21 years of age) where all growth plates within the acetabulum are fused. ... 03.164.008 Radiolucent Pelvic Retractor, for superior pubic ramus 03.164.029 Ø 2.5 mm Temporary Fixation Wire, length 220 mm …

Pelvic ring fractures often occur as part of a trauma comprising high energy impact. They still show an approximately 10% overall mortality [], mainly caused by exsanguination.The presacral venous plexus and the fracture surface are most likely the main source of bleeding [] and patients suffering from an unstable pelvic ring fracture have, according to the Tile classification type B and C ...6 DePuy Synthes Large Distractor–Femur Surgical Technique Universal Joint Assembly 1 Select a 14.0 mm threaded spindle (A) of appropriate length (most likely 480 mm). A transverse hole will be in the proximal end when applied to the femur. 2 Turn the end piece with double joint (B) onto the threaded

Did you know?

The Pelvic C-Clamp II is an emergency stabilization instrument that provides quick and efficient compression and stabilization of pelvic fractures in the emergency room, on the x-ray table, and in the operating room. It also works to control hemorrhaging in the unstable posterior pelvic ring. 1. Product Specifications.Synthes Pelvic Implant Set (125.885) Plates Catalog # Description 224.02 4.5 mm Narrow DCP Plate, 2 Holes, 39 mm Length (2) 229.33 4.5 mm Reconstruction Plate, 3 Holes, 45 mm Length (2) 229.34 4.5 mm Reconstruction Plate, 4 Holes, 61 mm Length (3) 245.00 3.5 mm Reconstruction Plate, 10 Holes, 118 mm Length (2)Synthes 3.0 mm Cannulated Screws, Long Thread With Cruciform Recess 36 mm. Synthes 3.5 mm Pelvic Cortex Screws, Self-Tapping With 2.5 mm Hexagonal Socket 22 mm. Synthes 2.4mm Cortex Screw Self-Tapping w/ T8 Stardrive Recess 24mm. Synthes 3.5 mm Pelvic Cortex Screws, Self-Tapping With 2.5 mm Hexagonal Socket 36 mm.synthes.vo.llnwd.net

Surgical Technique Step 1: Neck Osteotomy Step 2: Femoral Canal Preparation Step 3: Offset Selection & Head Trialing Step 4: Femoral Component Insertion. Open the catalog to page 11. 1. Vidalain JP (2011) The CORAIL Hip System: A Practical Approach Based on 25 Years of Experience. Springer; pg 94-101.Here are the costs of the inventory management software that we reviewed: Cin7: Starts at $349 per month. Ordoro: Free; $59 to $149 per month. inFlow: $89 to $439 per month when billed annually ...Variable Angle Locking Screw Technology. Variable angle (VA) locking screw technology allows freedom to choose screw trajectory up to 15° in each direction to avoid existing implants, prosthesis, or independent lag screws. A variety of lengths are available which allow for desired spanning of the femur. 4.Clinical Resources. Animation Ischial Screw Insertion. Instructions for Use. Intrapelvic Acetabular Plating System Brochure. Intrapelvic Acetabular Plating System Value Analysis Brief (VAB) Inventory Control Form. Surgical Technique Guide. Select all documents (3) Download Selected Items.synthes.vo.llnwd.net

The DePuy Synthes VA-LCP PPFx Proximal Femur Plating System 3.5/4.5/5.0 is con - traindicated for independent fixation if the hip stem requires immediate revision. The DePuy Synthes VA-LCP PPFx Proximal Femur Hook Plate 3.5/4.5/5.0 with 5 holes (shortest plate) is contraindicated for diaphyseal periprosthetic femoralVariable Angle LCP™ Elbow System. Product Codes: 02.107.002, 02.107.002S, 02.107.102... View More. PRODUCT CODES. DESCRIPTION. The Variable Angle LCP™ Elbow System utilizes the variable angle locking technology platform that is based on a common approach to implant design and instrumentation, reducing complexity and ensuring a familiar ...3 DePuy Synthes PPFx Proximal Femur Plating System - Usage Rationale. 08/04/2021. Windchill Document #0000312370. 4 DePuy Synthes PPFx Proximal Femur Plating System - Implant Shape and Profile Rationale. MM/DD/2021. Windchill Document #0000311044. 5 DePuy Synthes PPFx Proximal Femur Plating System - Distal Spanning Test Report. MM/DD/2021.…

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. The modular set for pelvic implants. The design of. Possible cause: The Small External Fixation System provides stable fi...

g Items for Systematic Reviews and Meta-analyses guidelines, a systematic search on PubMed and Google Scholar was performed. Articles included were in the English language or English translations and published between 2007 and 2018. Studies included were appraised with narrative data synthesis. Results: Twenty-five articles with 496 patients were included. These included 17 case series, with 3 ...02.118.408 7 holes, right 02.118.409 7 holes, left. 2.7 mm Variable Angle LCP Distal Tibia T-Plates. 02.118.306 4 holes 02.118.307 6 holes. Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. Inventory Control Form. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System.

Inventory Control Form Zero-P Patient Contact: Synthes (USA) To Click: (800) 523-0322 Synthes (Canada) Ltd. To Order: (800) 668-1119 Set: Institution: Surgeon: Procedure: Implantology 3.0 mm Ti. synthes matrix midface inventory control form · synthes css large inventory · synthes usf take · synthes tfna inventory control · synthes pelvic implant ...Cleaning & Sterilization Guidelines. Cleaning & Sterilization Guidelines for Synthes Trauma, CMF, Biomaterials and Spine Devices.

angels in waiting casa grande obituaries DePuy Synthes Medium External Fixator System devices may present issues if the MR imaging area of interest is in or near the area where the fixator frame is located. • For FFE sequence: scan duration 3 minutes, TR 100 ms, TE 15 ms, flip angle 15° and SE sequence: scan duration 4 minutes, TR 500 ms, TE 20 ms, flip angle ascend collinsville medical menumgm gift shoppe The DePuy Synthes Cannulated Compression Headless Screws are indicated for use in bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device. Screws are intended for single use only. Contraindications The implant should not be used in a patient who has gartic phone idea The literature summarized in this document is literature known to DePuy Synthes at the time of this document release and may be incomplete. AO Foundation is a third party medically guided, not-for-profit organization led by an international group of surgeons specialized in the treatment of trauma and disorders of the musculoskeletal system. used chevy 20 inch factory wheels and tiresbertas funeralthe amityville horror crime scene photos MatrixWAVE™ MMF System. 04.503.820, 04.503.821, 04.503.824.05... The MatrixWAVE™ MMF System is a bone-borne maxillomandibular fixation system that consists of wave-shaped plates that are attached to the mandible and maxilla with self-drilling locking screws. The dental arches can then be brought into occlusion by wiring around the plate ...The Pelvic C-Clamp is comprised of rails and arms with a locking mechanism. This allows a linear movement of the arms. The Pelvic C-Clamp should always be used in combination with the designated cannulated nails. Overview • Permits compression and stabilization of fractures or luxations of pelvic ring. the iron claw showtimes near marcus oakdale cinema Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J7184-C /09 Inventory Control Form 3.5 mm LCP Extra-articular Distal Humerus Plates (Stainless Steel and Titanium) Available nonsterile or sterile-packed. Add “S” to product number for ... usaa payoff overnight addressbank of america financial center roseville ca14 day forecast idaho falls A-Z Ortho 917 Lone Oak Rd Eagan, MN 55121 [email protected] Call 800.524.5194 Proud to offer products made in the USA.DIAMETER LENGTH. 03.113.024 2.8 mm 250 mm, 95 mm calibration. 3.5 mm Variable Angle Locking Screws, Self-Tapping, T15 Stardrive. LENGTH LENGTH.